Fechar

1. Identificação
Tipo de ReferênciaArtigo em Revista Científica (Journal Article)
Sitemtc-m16d.sid.inpe.br
Código do Detentorisadg {BR SPINPE} ibi 8JMKD3MGPCW/3DT298S
Identificador8JMKD3MGP7W/3E9Q9KG
Repositóriosid.inpe.br/mtc-m19/2013/06.12.01.41.02   (acesso restrito)
Última Atualização2013:07.16.19.09.48 (UTC) marcelo.pazos@inpe.br
Repositório de Metadadossid.inpe.br/mtc-m19/2013/06.12.01.41.03
Última Atualização dos Metadados2022:03.18.22.15.22 (UTC) administrator
DOI10.1016/j.jastp.2012.09.008
ISSN1364-6826
Rótuloisi
Chave de CitaçãoSchumannSabaSilvSchu:2013:ElFiCh
TítuloElectric fields changes produced by positives cloud-to-ground lightning flashes
Ano2013
MêsJan.
Data de Acesso29 mar. 2024
Tipo de Trabalhojournal article
Tipo SecundárioPRE PI
Número de Arquivos1
Tamanho852 KiB
2. Contextualização
Autor1 Schumann, Carina
2 Saba, Marcelo Magalhães Fares
3 Silva, Raphael Bueno Guedes da
4 Schulz, Wolfgang
Identificador de Curriculo1
2 8JMKD3MGP5W/3C9JHP6
Grupo1 GESATM-CEA-SPG-INPE-MCTI-GOV-BR
2 CST-CST-INPE-MCTI-GOV-BR
Afiliação1 INPE, BR-12201970 Sao Jose Dos Campos, SP, Brazil.
2 Instituto Nacional de Pesquisas Espaciais (INPE)
3 INPE, BR-12201970 Sao Jose Dos Campos, SP, Brazil.
4 OVE ALDIS, A-1190 Vienna, Austria.
Endereço de e-Mail do Autor1
2 marcelo.saba@inpe.br
Endereço de e-Mailmarcelo.pazos@inpe.br
RevistaJournal of Atmospheric and Solar-Terrestrial Physics
Volume92
Número6
Páginas37-42
Nota SecundáriaA1 B1 B1 B1 B1 B2 C
Histórico (UTC)2018-06-05 04:14:18 :: administrator -> marcelo.pazos@inpe.br :: 2013
2020-09-09 11:00:47 :: marcelo.pazos@inpe.br -> administrator :: 2013
2022-03-18 22:15:22 :: administrator -> simone :: 2013
3. Conteúdo e estrutura
É a matriz ou uma cópia?é a matriz
Estágio do Conteúdoconcluido
Transferível1
Tipo do ConteúdoExternal Contribution
Tipo de Versãopublisher
Palavras-Chavepositive lightning
preliminary breakdown
return stroke
electric field
ResumoPositive flashes correspond to approximately only 10\\% of the total number of flashes produced by a thunderstorm. However, strokes with high peak currents and long continuing currents are usually present in positive flashes. Therefore, positive flashes are responsible for more intense damage than the negative ones. Positive flashes often are preceded by significant and long duration intracloud (IC) discharge activity. We observe in detail the electric field variations produced by 80 cloud-to-ground lightning flashes in 9 different storms in S. Paulo, Brazil during the summers of 2009-2011. Intracloud discharges preceding the positive cloud-to-ground flashes and some characteristics of the electric field changes produced by the return stroke that occurred at ranges of 3-80 km from the site of the electric field measurements were analyzed. All flashes presented breakdown pulses prior to the return stroke. The mean time interval between the preliminary breakdown pulse (PBP) and return stroke was 157 ms. The pulse train duration have a mean value of 3.1 ms. Only 6 out of 80 cases analyzed did not present pulse trains but only one single bipolar breakdown pulse before the return stroke. In 95\\% of cases the initial breakdown pulse presented the same initial polarity of the succeeding return stroke. Time interval between pulses in a pulse train had a mean value of 280 mu s. The mean values of pulse width is 25.2 mu s. The mean values of zero-to-peak risetimes and of the 10-90\\% risetimes for 72 return strokes electric field waveforms are 9.5 and 5.7 mu s respectively. The AM value of peak amplitudes of the positive return strokes fields normalized to 100 km is 17.0 V/m. (C) 2012 Elsevier Ltd. All rights reserved.
ÁreaCST
Arranjo 1urlib.net > BDMCI > Fonds > Produção pgr ATUAIS > GES > Electric fields changes...
Arranjo 2urlib.net > BDMCI > Fonds > Produção anterior à 2021 > COCST > Electric fields changes...
Conteúdo da Pasta docacessar
Conteúdo da Pasta sourcenão têm arquivos
Conteúdo da Pasta agreementnão têm arquivos
4. Condições de acesso e uso
Idiomaen
Arquivo Alvo1-s2.0-S1364682612002295-main.pdf
Grupo de Usuáriosadministrator
marcelo.pazos@inpe.br
simone
Visibilidadeshown
Política de Arquivamentodenypublisher denyfinaldraft24
Permissão de Leituradeny from all and allow from 150.163
Permissão de Atualizaçãonão transferida
5. Fontes relacionadas
VinculaçãoTrabalho Vinculado à Tese/Dissertação
Repositório Espelhoiconet.com.br/banon/2006/11.26.21.31
Unidades Imediatamente Superiores8JMKD3MGPCW/3F2PBEE
8JMKD3MGPCW/3F3T29H
DivulgaçãoWEBSCI; PORTALCAPES; AGU; MGA; COMPENDEX; SCOPUS.
Acervo Hospedeirosid.inpe.br/mtc-m19@80/2009/08.21.17.02
6. Notas
Campos Vaziosalternatejournal archivist callnumber copyholder copyright creatorhistory descriptionlevel format isbn lineage mark nextedition notes orcid parameterlist parentrepositories previousedition previouslowerunit progress project readergroup rightsholder schedulinginformation secondarydate secondarykey session shorttitle sponsor subject tertiarytype url
7. Controle da descrição
e-Mail (login)simone
atualizar 


Fechar